Czone Signal Interface SI
Czone Signal Interface SI connects the CZone system to external sensors, alarms and switching devices. The Signal Interface provides intelligent, automated control of power circuits, dependent on input status.
296,70 €
51,49 €

Description
Czone Signal Interface SI
Czone Signal Interface SI with seal and connector
The Signal Interface connects the CZone system to external sensors, alarms and switching equipment. The Signal Interface provides intelligent, automated control of circuits, dependent on the input status.
- Accepts input from traditional switches used to control output voltages.
- Accepts input from switches that initiate alarm signals (e.g. float switch).
- Accepts input from industry standard tank sensors (0-5V, 10-180 Ohm, 240-33 Ohm).
- Accepts input from general voltaic or resistive signals used to control output voltages or indicate physical position (e.g. hatch partially open).
- LED status indication for each input.
- Output standard NMEA 2000 protocols.
- Resistive input range 0–1000 Ohm.
- Voltage sensing input range 0–34 V DC.
Note: High and low alarm levels can be defined for all inputs.
General specifications
Dimensions, hxwxd 100 x 156 x 42 mm
Protection degree IPX5 water resistant